Pune, Maharashtra
GST No. 27AMXPG6297L1ZZ
Approx. Rs 80,000 / PieceGet Latest Price
Product BrochureProduct Details:Rated Voltage | 415 V |
Automation Grade | Automatic |
Voltage | 415 V |
Phase | Three Phase |
Country of Origin | Made in India |
Rated Current | Upto 5000 Amps |
Body Material | Mild Steel |
Surface Finish | Color Coated |
Frequency | 50 Hz |
LT APFC SYSTEM Reactive Power compensation system is designed to work automatically on LT power supply to measure, display & connect/ disconnect the required capacitor banks through Contactor with protection of MCB / HRC Fuses & series reactors(0.4% OR 7.0%) to each bank, to achieve the set Target power factor. Contactor Switched Automatic power factor system is the highly accurate, properly designed system with required creep age distances as per required standards. APFC System equipped with advanced, digital Microprocessor based Relay to measure, calculate and display all electrical network parameters. It accurately measures cycle to cycle Reactive Power requirement for set target power factor & initiate command to Switching element /device installed in the system, so as required capacitors are connected /disconnected to the network. APFC controllers close loop fast response multi method switching [MMS] algorithm that helps system to have close & precise control on power factor. APFC Relay has memory storage model of capacity 45 Days on hourly basis with RS 232 port for communication. Separate module is available with one year storage capacity with adding SD card and interfacing facility.
Approx. Rs 4 Lakh / UnitGet Latest Price
Product BrochureProduct Details:Minimum Order Quantity | 1 Unit |
Phase | Three Phase |
Frequency | 50 Hz |
Country of Origin | Made in India |
Voltage | 440 V |
Ambient temperature | 45 Degree C |
Max. Rated Current | 6300 Amp |
Surface Finish | Color Coated |
Body Material | Mild Steel |
This high-speed real-time Automatic Power Factor Correction Panel comes with suitable Tune and Detune harmonics filter. Gloabtel ensures that they compensate the reactive power required by any load requiring PF correction in a very short time (less than 20 ms), thereby reducing failure in sophisticated equipment. Maintaining unity PF, reduction in KVA demand, reduced electricity bills, enhanced capacity of transformer, switchgear, HT cable are few of the benefits accrued.
Features:
Best possible power factor correction and filtering
Helps in reducing the total harmonic distortion in the system
No risk of congestion cables and nuisance tripping of fuses or relays
Disturbances in telecommunications and data transmission are minimized
Electronics, motors control systems, converters and generators function devoid of interruption
Explore More Products
© Om Power Systems. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited